    Emerson/Vertiv R48-series CAN programming?

    Hai om, Is your setup working well? can you share a report of the results?
  2. R

    Emerson/Vertiv R48-series CAN programming?

    found the solution, the problem was in the bluetooth serial app, it considered the command "10"(53.5V) as "1"(43V). the solution simplifies the commands to just 9 commands. now the psu can be set up to 58V. thanks all.
  3. R

    Emerson/Vertiv R48-series CAN programming?

    Thank you, I will try again manually without the Bluetooth serial app. hope it works.
  4. R

    Emerson/Vertiv R48-series CAN programming?

    I'm making a project using serial Bluetooth and managed to set the DC output on, limit current, voltage 41v - 48v, except that setting the voltage above 48v didn't work. for example, if the psu voltage is 41v then I set it to 48v it immediately changes. but from 48v to 53v it gets 43v instead. I...
  5. R

    Emerson/Vertiv R48-series CAN programming?

    Thanks for the reply, maybe I gave the wrong command, I'll try again.
  6. R

    Emerson/Vertiv R48-series CAN programming?

    found another problem with the psu, the voltage could not be set above 48v, when I tried to set it to 49v - 58v the psu instead changed to 43.5v. i tried it on r48-2000e3 and r48-1000, online and offline commands. both same respond
  7. R

    Emerson/Vertiv R48-series CAN programming?

    In my country the electricity uses 220v voltage. and I connected 2 psu in the same phase.
  8. R

    Emerson/Vertiv R48-series CAN programming?

    Yes i have set both to 1.20% current limit with offline command (default), along with setting output on, walking time, default voltage. and everything seems to work. I use this command for set current 03 F0 00 19 3F 99 99 9a (1.20%)
  9. R

    Emerson/Vertiv R48-series CAN programming?

    Thank you friend. if the problem is in the r48-1000 then I will try setup 2x r48-2000e3 and hope that the current can be close to 1C. I found chart for r48-1000
  10. R

    Emerson/Vertiv R48-series CAN programming?

    Yes om... i set current limit both PSU to 1,20%. And this my sketch on arduino for your reference. Using mcp2515 and esp32.
  11. R

    Emerson/Vertiv R48-series CAN programming?

    today i tried charging at an ac charging station with a new setup, vertiv r48-2000e3 and emerson r48-1000 in series. the battery only draws 7.5a, the same as the previous 2x r48-1000 setup. finally I paralleled it with a 24s lifepo4 charger 10A to get close to 1C. I'm still confused, is the...
  12. R

    Emerson/Vertiv R48-series CAN programming?

    After many experiments you have done with emerson, eltek, huawei, etc, which PSU do you recommend for use as a charger, looking at its power, durability, communication, and when they are connected in series or parallel?
  13. R

    Emerson/Vertiv R48-series CAN programming?

    Thanks mate. I want to ask again because I'm new for this, is it okay to connect 2 psu in series with different voltages? as you said 24v and 48v?
  14. R

    Emerson/Vertiv R48-series CAN programming?

    Hai friend.. I want to ask you, I have the same problem when connecting in series, 1 psu 43v, 1 other psu drops to 33v. The current is only 7.5a from a maximum of 20a. is this normal? What if I add 1 psu 48v 40a set to 43.8v, then I series it with the 2 previous psu that I paralleled at 43.8v...
  15. R

    Emerson/Vertiv R48-series CAN programming?

    I think this is the old version. I bought it in used condition. The goal is to get a 20A charger. Compared to buying a new LifePo4 charger 20A, the price is much cheaper. Im so happy now :D