    A different approach to battery management...

    Hi Gary. If you recall I bought your last three lvc boards awhile back. I was having trouble getting them to activate the lvc via the brake.  Come to find out I think 2 of the boards are bad. One of them has a transistor that gets very hot. The other is high when pack is fully charged.  One...
  2. A

    A different approach to battery management...

    Yes, that will work fine. The opto ground/- connection goes to the black controller brake wire and the yellow would go to the opto + connection. -- Gary
  3. A

    A different approach to battery management...

    48V Controller (Model LB37) Yi-Yun Brand Controller Electrical Parts - 101210 Shipping Weight: 1.0 lbs. This 48 volt controller has 7 connectors. Rated Voltage 48 Volts. Max Current 50 Amps. Useable Motors: 800 to 1500 Watts. its on the TNC scooters site...
  4. A

    A different approach to battery management...

    So maybe i am not understanding the opto out of the current LVC boards that i have. i simply tied the red wire from each of the 3 LVC's out together - same with the black wires and then connected to red and black of the controllers BRAKE input? I cant tell if its actually working - i did loose a...
  5. A

    A different approach to battery management...

    your saying you only need one but that means individually plugging and unplugging for each group 3 separate times. I could just connect to my hyperion duo? so its confirmed i need the full monty!
  6. A

    A different approach to battery management...

    I have a 18S2P Lipo config 6S x6 5800 Turnigy Lipo approx 75v off the charger. i am trying to understand the difference between Lvc/hvc board + charge controller + battery medic and the full v4 BMS? today i have a 75v lipo charger that charges at 5A but its not a balancer. i want to plug it...
  7. A

    Even Newer 4 to 24-cell Battery Management System (BMS)

    seems like they are trying to fix some difficult bugs in their close to final design. until they fix them and have a run of the boards that are defect free i dont think they know. their are a lot of us on this board that have projects that need this yesterday.
  8. A

    Headway Battery rust

    make sure you dont have any pool chemicals like cholorine or acid or fertilizer. these combine with the humidity and cause corrosion on everything. I too live in South Florida.
  9. A

    Even Newer 4 to 24-cell Battery Management System (BMS)

    so im clear. i connect these BMS boards to the balance taps coming from my LVC boards. I connect one side of the BMS to my power supply and the output of the BMS to the battery pack
  10. A

    Even Newer 4 to 24-cell Battery Management System (BMS)

    really looks good. this is like waiting for 9 months to have a baby!
  11. A

    Even Newer 4 to 24-cell Battery Management System (BMS)

    Gary, i noticed you are now out of your trick LVC setup? when will you have more. i fried one of my turnigys while waiting for the 4.0 BMS? 3/4/5/6-Channel LVC + 3p/4p Parallel Adapter Details New 3, 4, 5 or 6-Channel LiPo Low Voltage Cutoff Protection Circuit + Parallel Adapter Kit...
  12. A

    Even Newer 4 to 24-cell Battery Management System (BMS)

    i could wind up with the same issue so interested in the response. Also - how are we doing with the 4.0 in terms of when can we order?
  13. A

    Even Newer 4 to 24-cell Battery Management System (BMS)

    Keep it simple and keep the price low.