Recent content by porrascarlos80

  1. P

    Fullriver LiFePO4 32700 (box of sixty)

    hello all, these seems to be the specs for it https://www.fe123battery.com/en/product_show.php?id=19 not powerfull for ebikes, but for my application which is solar , its great. now trying to set up my solar charge controller for the right parameters....
  2. P

    Under discharge 1 cell went low

    What could be the reason? Could it be the point in the battery string to which i connected the inverter? Maybe its better to connect it to the middle of the battery bank? I will try to attach pictures
  3. P

    How to connect 2 PV strings

    Agree. I ordered blockind diodes
  4. P

    How to export active balancer data

    https://www.amazon.com/Equalizer-Battery-Balancer-Capacitors-Continuous/dp/B07SB5WZ17/ref=mp_s_a_1_1?keywords=1a+active+balancer&qid=1584841969&sr=8-1
  5. P

    How to export active balancer data

    I want to view the data of the active balancer remotly. Any idea to export it to a web page?
  6. P

    Why charge controller didnt stop

    he is the link for the same charge controller I am using https://syonyk.blogspot.com/2018/05/whats-difference-between-150-and-600.html
  7. P

    Why charge controller didnt stop

    Ithanks I was under the idea the charge controller would stop charging by itself without needing an external relay. I hsve another setup lead acid with tracer 40 amps and battery doesnt overcharge 14.5 volts Tracer stops i will lower the voltage and test goid idea! I saw by default this...
  8. P

    Why charge controller didnt stop

    I was expecting it to finish at 28v not to continue over charging i will change to custom battery and validate
  9. P

    Why charge controller didnt stop

    Values set 28vdc Lcd shows 28.1 Fluke and Active balancer shows higher voltage Why? https://youtu.be/v8UzkX0mP-A
  10. P

    Where should I connect by Solar charge controller A or b?

    friends, shall I connect to the beginning of my battery string or to the end ? A or B from the attached picture? My concern , if I connect to B , the inverter may ask for energy directly from the solar charge controller forcing above his capacity and burning something. The good think is...
  11. P

    Pv shunt trip

    I wan to cut any voltage / current from my panels in case of emergency automatically. I dont want any powe to go into my batteries from the charge controller. I have already a manual disconnect but want to have automatic option.
  12. P

    Pv shunt trip

    In case of emergency -high temp -cells under or over voltage I need a 12 vdc shunt trip to shutoff the Pvs. Any advice on which one to buy? Amps 80 Thank you