Recent content by smotors

  1. smotors

    Votol EM-100 & EM-150 controllers

    ...can be connected to a controller that can work without sensors and check the motor. if the fire was strong, the magnets could be damaged. But they are separated from the body by an air gap, which does not transfer heat well. It can be assumed that the magnets have not lost their quality. At...
  2. smotors

    Votol EM-100 & EM-150 controllers

    ... the question is, can the parameter EBS ratio regulate the recuperation level?
  3. smotors

    Votol EM-100 & EM-150 controllers

    earlier there was already information that it is impossible to leave blank forms.
  4. smotors

    Votol EM-100 & EM-150 controllers

    ...additional connection is not required. There is already a connection inside the controller.
  5. smotors

    Votol EM-100 & EM-150 controllers

    ...it probably is. I had a similar case.
  6. smotors

    Votol EM-100 & EM-150 controllers

    ..look in the window "Display" the state "Fault display", and why in the right additional window You have a check for "reverse" ?
  7. smotors

    Votol EM-100 & EM-150 controllers

    ...the connection between key lock and B+ is it really good?
  8. smotors

    Votol EM-100 & EM-150 controllers

    Thank You. This is important information.
  9. smotors

    Votol EM-100 & EM-150 controllers

    I want to make the correct settings. what do these parameters mean in each window? how do they work?
  10. smotors

    Votol EM-100 & EM-150 controllers

    This can be the Hall angle and the correct connection of the phase and hall wires. You can try changing the alternation.
  11. smotors

    Votol EM-100 & EM-150 controllers

    who knows what this effect is? ..When the engine speed increases, a high frequency sound is emitted at a certain moment. the current immediately increases slightly. When I connected the oscilloscope, I saw a decrease in the PWM frequency from 15 kHz to 8 .. Is this done to improve control at low...
  12. smotors

    Votol EM-100 & EM-150 controllers

    ...to enter the calibration mode, you need to remove 0, and with the key pressed " Shift", press twice " ~ " about regenerative braking. During the tests, did you use a battery or other current source? The battery protection system will not damage it.
  13. smotors

    Votol EM-100 & EM-150 controllers

    Controller setup succeeded). The motor rotates without load stably in all modes. I am glad. There will be more settings when working with the load. Thanks for the help. )
  14. smotors

    Votol EM-100 & EM-150 controllers

    what does this parameter mean? how to set it up correctly?
  15. smotors

    Votol EM-100 & EM-150 controllers

    Thank You. Very useful information for me. The further, the more I learn to configure the controller. :thumb: