I testet a 200A JK-B2A-24S to "death" with an electronic load.
3x400A for 30 seconds , 3x450A for 20Seconds was no problem 3x500A für 10 seconds was also ok.
Then I tested it with 500A for 20seconds. After 15 seconds it turned completly off without any visible defect components. All the Fets and the shunts are still ok.
I think it was a software based 2nd level short circuit protection, which turned of the BMS completly.
I now use the version with integrated heating controller with 400A settings and it is doing fine since 8000km and nearly two years.
3x400A for 30 seconds , 3x450A for 20Seconds was no problem 3x500A für 10 seconds was also ok.
Then I tested it with 500A for 20seconds. After 15 seconds it turned completly off without any visible defect components. All the Fets and the shunts are still ok.
I think it was a software based 2nd level short circuit protection, which turned of the BMS completly.
I now use the version with integrated heating controller with 400A settings and it is doing fine since 8000km and nearly two years.